Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80

    Buy cheap Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80 from wholesalers
     
    Buy cheap Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80 from wholesalers
    • Buy cheap Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80 from wholesalers
    • Buy cheap Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80 from wholesalers
    • Buy cheap Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80 from wholesalers

    Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80

    Ask Lasest Price
    Brand Name : VOTESEN
    Model Number : VMG600
    Certification : CE
    Price : USD249-770
    Payment Terms : T/T, Western Union, MoneyGram,paypal,Visa,Mastercard
    Supply Ability : 10000set/month
    Delivery Time : 7-15 working days
    • Product Details
    • Company Profile

    Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80

    Digital sanitary low price electromagnetic flowmeter,sewage water magnetic flowmeter electromagnetic water sensor DN80

    Product Parameters

    Items
    VMG600 Electromagnetic flowmeter
    Nominal diameter
    DN10-3000mm
    Pressure
    0.6~4.0MPa ( Special pressure customizable)
    Flow range
    0.1~15m/s
    Structural style
    Integrated type , Split type , Insert type, Battery powered type
    Protection Class
    IP65, IP68 optional
    Medium Conductivity
    ≥20μs/cm
    Liner Material
    PU, PTFE, CR, FPM, F46, PFA
    Accuracy
    Indicated value ±0.5%, Optional values ±0.3%
    Electrode material
    HB, HC, WC, 316L, Ti, Ta, Pt
    Connection
    Flange Clamp Thread
    Signal output
    Pulse / 4~20mA / RS485 / HART/Modbus

    Product Feature

    VMG600 series electromagnetic flowmeter is manufactured using the latest technology of contemporary electromagnetic flow, and has the following characteristics:

    1. The measurement medium is not affected by the density, viscosity, temperature, pressure and conductivity of the fluid

    2. There are open flow parts in the measuring pipe, no pressure loss, and low pitch is required for straight pipe. It is suitable for
    sewage, mud and other complex conditions

    3. Reasonable selection of electrode and lining material has good corrosion resistance and wear resistance, and the operation of high-definition backlight LCD is simple.

    4. Full digital processing, strong anti-interference ability, reliable measurement, high precision, flow measurement range up to 150:1, with self-test and diagnosis function 5.16 bit embedded microprocessor, RS485, Hart and MODBUS digital communication signal output (optional)


    Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80

    Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80



    How to order?

    (A) How to choose Lining material?


    Lining Material
    Applications
    PTFE
    Strong corrosive mediums such as strong acid and alkali-20 ~ 120℃
    F46
    The same as PTFEApplicable in medium of low abrasion
    -40 ~ 160℃
    PFA
    The same as F46.

    Applicable in state of load pressure-40 ~ 160℃
    Neoprene
    Water, sewage and slurry, mineral serosity of low abrasion-20 ~ 60℃
    PU
    Applicable in mineral serosity, slurry and coal slurry of high abrasion-20 ~ 60℃

    (B) How to choose Electrode material?

    Electrode Material
    Applications
    SS316L
    Applicable in water, sewage and corrosive mediums.
    Tungsten carbide
    Applicable in mediums of no corrosive and low abrasion.
    Hastelloy B (HB)
    Having strong resistance to hydrochloric acid of any consistance.
    Hastelloy C (HC)
    Resistant to oxidable acid such as nitric acid, mixed acid etc.
    Titanium
    Seawater, and kinds of chloride, hypochlorite salt, oxidable acid etc.
    Tantalum (Ta)
    Hydrofluoric acid, fuming sulfuric acid, alkali remaining chemicals etc.
    Platinum-iridium
    Chemical mediums except for aqua fortis, ammonium salt.

    Based on your application and working environment, you shall provide us with the below details.


    1. Pipe Diameter:
    2. Nominal Pressure:
    3. Lining Material:
    4. Electrode Material:
    5. Body Material:
    6. Explosion Proof: Yes/No
    7. Shell Protection:
    8. Type: Integrated/Segregated
    9. Power Supply:
    10. Signal Output:
    11. Communication:
    12. Other requirements:


    If you need more specification details, please get in touch with us.

    Quality Digital Sanitary Electromagnetic Flow Meter Electromagnetic Water Sensor DN80 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xian Votesen Electronic Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)